If you hear that the blower motor is operating but don't feel any air flowing through the vents, the problem is with the airflow controls [source: RepairPal]. If the blower motor isn't running you should: Use voltmeter or ohmmeter to check for a blown fuse.
Is there a fuse that controls the blower motor?
Many vehicles have two fuses for the blower motor, one in the interior fuse block and the other under the hood. The blower motor is usually under the dashboard on the passenger side.
How do I know if my heater fuse is blown?
You can quickly determine by checking resistance with a multimeter. A good fuse will have nearly zero ohms of resistance, if the fuse is blown there will be no reading.
What happens when a blower motor relay goes bad?
If the blower motor relay develops any sort of problem that hinders its ability to properly limit and distribute power, it may cause the blower motor fuse to blow. Any sort of electrical spikes or excessive current from a bad relay will blow the fuse and cut power in order to protect the system.
What can cause a blower motor to stop working?
In most cases, a blower motor resistor fails due to corrosion or overheating. Sometimes, the mechanical resistance to the motor rotation causes an excessive electric current that can overheat and prematurely damage the blower motor resistor.
Where is the blower motor fuse and relay?
Under the instrument panel, look under the glove box. On the right side of the fender wall you will find another fuse box. The blower motor fuse is easy to replace.
How do you tell if a fuse is blown without a multimeter?
Put one wire to neutral/common, and one wire on the line side of the fuse. If voltage is present the bulb will light up. Now move the wire from the line side to the load side of the fuse. If the fuse is good the light will come on.
Will a blown fuse cause my heater not to work?
Faulty Wiring or Blown Fuses Similar to your broken HVAC controls, your car's wiring could be broken or have a short in it. This would mean the heater isn't triggered when the driver commands it to function.
Where is the blower motor relay fuse located?
Under the instrument panel, look under the glove box. On the right side of the fender wall you will find another fuse box. The blower motor fuse is easy to replace.
What relay controls the blower motor?
The blower motor relay controls the current used to power the blower motor, and is subject to the constant on and off switching.
Where is the blower motor relay?
The blower motor relay is generally located in the under-hood fuse box or in the under-dash fuse box. A blown fuse can mimic relay failure. A failed blower motor switch can also give many of the same symptoms.
How do I test a blower motor relay?
Connect a test light or multimeter to the ground (black lead). Turn the ignition key to the on position (engine off), and remove the relay. Using the probe, test all terminal sockets in the relay connector. Two of the four should have power.
What happens when the blower motor resistor goes out?
If the resistor shorts or fails, it may cause the blower motor to remain stuck on one fan speed. The heating and air conditioning systems may still function at one speed, however the resistor will have to be replaced in order for full functionality to be restored.
Where is the blower motor reset button?
Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.
What causes heater blower not working?
If little air is coming through the vents (hot or cold), then it could be because the blower motor for the fan or a switch or resistor that controls fan speed isn't working. Another cause might be that the electronically controlled “blend doors” that direct air flow are stuck or broken.
How can I tell if a relay is bad?
You want to feel and listen for any clicks. If you feel and hear clicks, the relay works on one side – the side with the energizing circuit and coil. However, if there was no sound from the horn, the relay has a problem along the contact circuit.
How much does it cost to replace a blower motor?
How much does it cost to replace a blower motor in a car?
What causes heater blower not working?
If little air is coming through the vents (hot or cold), then it could be because the blower motor for the fan or a switch or resistor that controls fan speed isn't working. Another cause might be that the electronically controlled “blend doors” that direct air flow are stuck or broken.
How do you test a blower motor relay?
Connect a test light or multimeter to the ground (black lead). Turn the ignition key to the on position (engine off), and remove the relay. Using the probe, test all terminal sockets in the relay connector. Two of the four should have power.
How many blower motors are in a car?
The number of blower motors in your vehicle depends on its climate control system. Some cars have one blower motor, but that may not be the case for some SUVs and vans. They may have two motors, one in the heater box and another in the vehicle's rear area.
What happens when blower motor resistor goes out?
If the resistor shorts or fails, it may cause the blower motor to remain stuck on one fan speed. The heating and air conditioning systems may still function at one speed, however the resistor will have to be replaced in order for full functionality to be restored.
How can I tell if a relay is bad?
You want to feel and listen for any clicks. If you feel and hear clicks, the relay works on one side – the side with the energizing circuit and coil. However, if there was no sound from the horn, the relay has a problem along the contact circuit.
How much does it cost to replace a blower motor relay?
The blower motor is operated by an electrically operated switch, called a relay. If the relay fails, the motor's fans will not blow conditioned air into your car. Fixing the relay usually costs around $50 to $80. So, if the blower motor relay fails, you could be left sweating or shivering.
Will a blower motor work without the resistor?
Without any power, the motor won't run. As a result, the blower fan stays still and silent, and no air blows out of the vents. There are instances where a bad resistor will prevent the current from reaching the blower motor altogether.
Why is my blower not working on my AC unit?
In air conditioning mode, check the indoor unit for ice around the evaporator coil and refrigerant lines. If the fan is not working, the coil could freeze. With a frozen coil, air will not pass through until the ice melts. You should shut off the air conditioning immediately.