Blower Issues The most common reason for a furnace running but not blowing air is likely due to issues with the blower or blower motor. The blower is responsible for pushing air out of the registers and when it fails no air will come out.Furnace Fan Running But No Air Coming Out Of Vents
Plugged air filter or too restrictive
Duct work plugged or falling apart
Insulation loose inside duct work
Dirty indoor air conditioning coil
Low on refrigerant causing coil to freeze over
Squirrel cage fan blade dirty
Indoor fan motor or capacitor failing
Why is my furnace running but not producing heat?
Dirty filters are the most common cause of furnace problems. Dust and dirt restrict airflow—and if the filter gets too clogged, the heat exchanger will overheat and shut off too quickly, and your house won't warm up. If the blower is running but no heat is coming out, replace the filter.
Why is air not coming out of my vents?
Vents Blockage If you feel no air is blowing from vents in your house, vent blockage is most likely to be the issue. You might be blocking your air vents unknowingly; a piece of furniture might be in front and blocking the airflow, or you might have closed some vents on a chilly day and forgotten to open them again.
How do you reset a furnace blower motor?
Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.
How do I check the airflow on my furnace?
Stand in front of the furnace and look for the ducts. Pull the old filter out and discard it. On the new filter, find the arrow indicating the proper airflow direction. The arrow must face toward the furnace and away from the return duct that pulls the air in need of heating or cooling.
How do you check for clogged air ducts?
Turn on the heat or the air conditioning of your HVAC system. When the fan begins to blow, check all of the vents in each room for airflow. If there is a noticeable lack of blowing air through a specific vent, the duct may be blocked.
How do you know if the furnace blower motor is bad?
Poor or Airflow from Air Vents This will be the first and most obvious sign your blower motor has a problem. It may or may not indicate that you need a replacement motor. If there is no air or very weak airflow coming from the air vents, the motor may be clogged, or it may be malfunctioning.
How do I know if my blower motor is bad?
If the blower motor is completely bad, then you'll have no airflow at all. Strange sounds coming from blower. Blower motors can make all kinds of sounds, depending on what the issue is. Vibrations, grinding, and high pitched-noises are some of the sounds a blower can make if it's going bad.
How much does it cost to replace furnace blower motor?
On average nationwide, a furnace blower motor replacement costs $400 to $600, including parts and labor. A single-speed blower motor costs around $450 to replace while a variable-speed motor costs $600 or more. You'll also need to budget labor, about $75 to $125 per hour.
Why is my furnace blowing cold air instead of heat?
If your furnace is blowing cold air in your home, this is a sign of an issue with the flame detector, gas supply, air filter, pilot light, or condensate lines. Many of these issues are able to be easily solved on your own by sanitizing or replacing components in the gas furnace.
Why is cold air coming out when the heat is on?
This issue could be caused by an improper thermostat setting. Check that the fan blower switch is set to “auto” and not “on.” When the “auto” setting is chosen, the fan will only run during a heating cycle and won't push air that feels cooler through the vents in between cycles.
Why is my pilot light on but no heat?
If there's a pilot light, make sure that it's lit and touches the thermocouple. If it's lit but the burners don't heat, feel the side of the furnace. If it's cool, the problem might be the thermostat, gas valve or control board. Make sure that the gas valve is on and that there's enough fuel.
How long does it take for a furnace to reset?
Press and hold the reset button for about 30 seconds. Raise your thermostat to the desired temperature. This should ignite your furnace. If there's no ignition, then it's time to call a professional.
Why does a furnace need to be reset?
The basic purpose of a reset button is to serve as a safety feature. It helps shut down the furnace when the furnace is too hot. This essentially prevents the overheated furnace from triggering the circuit breaker. As noted above, a furnace may need to be reset sometimes, such as when it is too hot.
What happens if you put the furnace filter in backwards?
When a furnace filter is placed backwards, the fibers can't do their job properly. This means your furnace has to work harder to generate the same air flow, resulting in increased energy costs. Particles are also allowed to build up irregularly, making the furnace working even harder to draw air.
What happens if I put my air filter in backwards?
If you set your filter up backwards, the normally collective end of the device will not face the air supply. In effect, your filter will help keep debris in the air. This results in a clogged filter and improperly cleaned air when it reaches your lungs.
How often should you change furnace filter?
A good rule of thumb is to change 1-2 inch filters every three months, 4 inch filters every six months and 5 inch filters every 12 months. Signs your air filter needs changed: The filter is visibly dirty. Certainly if you can't see the material of the filter itself, it should be replaced.
Can I clean my air ducts myself?
When it comes to the nitty gritty, cleaning air ducts is not a do-it-yourself job. It requires tools, such as a high-powered vacuum and rotary brushes, that you don't have lying around in the garage. In addition, an improper cleaning job could damage the ducts, resulting in expensive repairs.
Do furnace vents need to be cleaned?
EPA does not recommend that the air ducts be cleaned routinely, but only as needed. EPA does, however, recommend that if you have a fuel burning furnace, stove or fireplace, they be inspected for proper functioning and serviced before each heating season to protect against carbon monoxide poisoning.
How long should a furnace blower last?
How long does it take to replace a blower motor in a furnace?
It takes between 45 to 90 minutes for a HVAC specialist to: replace the blower motor, adjust it, clean the fan, test it and assemble the furnace back together. The biggest challenge if you're doing it yourself is getting the assembly out.
What causes blower motor failure?
Blower motor breakdown can be the result of anything from old age to failed bearings, high amp draw, electrical failure in the windings, dirt accumulation, and more. “The most common cause is dirt accumulation due to lack of maintenance,” said Tom Beaulieu, president of Bay Area Services Inc.
Where is the reset button on my furnace?
Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.
Why is cold air coming out of my vents?
Clogged air filters could be causing cold air to blow out of your vents. A dirty air filter can block airflow over your furnace's heat exchanger, which can cause it to overheat.
Is the outside unit supposed to run when the heat is on?
The heating system is largely isolated to the interior. When you have a standard furnace, the outside AC unit shouldn't run at all. The interior system works with a few steps designed into it. As you activate the heater, a pilot light or electrical-heating element turns on.
Can hear your furnace click on but it does not fire up?
You Have a Faulty Ignition Sensor (Pilot Light) The pilot light or ignition sensor is usually the most common issue when your furnace will not ignite. This is typically the problem if you can hear your furnace click on but it does not fire up.
Why is my furnace blower fan not blowing cold air?
The blower fan doesn’t work When your furnace is running, but it doesn’t blow air (no matter if it’s cold, warm, or hot air), and you’ve ruled out the thermostat, air filters, and circuit breakers, the blower fan could cause the problem.
Why does my furnace stop running when I turn it on?
Even if you think that the furnace is still running, it has overheated and stopped because of the clogged air filter. 7. The Circuit Breaker Is damaged Modern and complicated furnaces today come with circuit breakers.
What happens when you turn off the blower on your furnace?
If you turn your furnace off or the room becomes sufficiently heated to the point where there furnace halts automatically, the limit control switch shuts the blower off to save energy. Likewise, when the heating coils warm, the control switch kicks the blowers on to disperse the heat through your household air ducts.
Why is my central AC running but not blowing air?
If your central AC is running but not blowing air, your unit’s fan capacitor is bad or experiencing failure. When working properly, the capacitor sends an energy surge to your AC’s outdoor and indoor fan motors and compressor running, helping blow cold air into the room.